Column load cell / SM-S4A column load cell
Product Categories Column sensor
SM-S4A series weighing sensors use American raw materials and BH series foil strain gauges produced by the proprietary processing technology of BEAN Company of the United States as force-to-electric conversion elements. The load-bearing method is a compression structure, with good automatic self-aligning function, waterproof and dustproof, easy to install and use, which fully meets the requirements of large-tonnage weighing. It can be used to manufacture electronic truck scales, dynamic track scales, large-tonnage hopper scales, and industrial weighing and material level control of large-tonnage silo hoppers.
SM-S4A series weighing sensors use American raw materials and BH series foil strain gauges produced by the proprietary processing technology of BEAN Company of the United States as force-to-electric conversion elements. The load-bearing method is a compression structure, with good automatic self-aligning function, waterproof and dustproof, easy to install and use, which fully meets the requirements of large-tonnage weighing. It can be used to manufacture electronic truck scales, dynamic track scales, large-tonnage hopper scales, and industrial weighing and material level control of large-tonnage silo hoppers.
Features
Protection grade IP67, suitable for harsh environment.
Good dynamic response and strong anti-overload capability.
Performance is stable and reliable for a long time.
Dimensions (In mm. 1mm=0.03937 inches)


Circuit Diagram
Red: | +input | red: | + Motivation |
Blue: | -input | blue: | -excitation |
White: | +output | White: | +Signal |
Yellow: | -output | yellow: | -Signal |

Specification Technical parameters:
Project Type | Technical parameters |
Measuring range Nominal load range | 40~300t |
Operating voltage Power supply | 10~12 VDC |
Zero balance Zero balance | 1.0±% of rated output |
Analog Output Analog output | 2.0±0.01mV/V |
Input Impedance Input resistance (Rlc) | 750±20Ω(ohms) |
Output Impedance Output resistance (Ro) | 700±5Ω(ohms) |
Insulation resistance Insulation resistance | ≥5000 MΩ(Mege-Ohms) |
Comprehensive accuracy Class precision | 0.3%F.S |
Temperature drift Effect of temperature | 0.03%F.S/10℃ |
Operating temperature Operating temperature | -40~+85℃ |
Safety overload Safe Load Limit | 200% FS |
Plastic deformation limit Safety margin against yielding | 300% FS |
Body fracture limit Safety margin against breakage | 500% FS |
Material Material | High performance alloy steel or (chromium ratio greater than 15% stainless steel) High performance alloy steel or (chromium ratio>15% stainless steel) |
Protection level Protection type | IP67/IP68 |